Endurance of Compacted Steel Wire Ropes

Authors

  • Halvor Torgersen Norwegian Forest Research Institute (NISK), Ås, Norway

Abstract

This paper describes an investigation of fatigue resistance in different steel wire rope constructions used in Norwegian cable logging operations. Test results indicate the following: - A clear difference in fatigue resistance between ropes (approximately 50% decreased endurance for the compacted rope of highest density). - Differences in rope wear for varying angles of deflection. - A correlation between the number of visible broken wires and remaining strength in the rope.

Downloads

Published

2000-07-07

Issue

Section

Technical Papers