Performance of a Differential GPS in Dynamic Mode Under Sitka Spruce Canopies
Authors
N. M. Holden
University College Dublin, Ireland
F. Criado Delgado
University College Dublin, Ireland
P. M. O. Owende
University College Dublin, Ireland
S. M. Ward
University College Dublin, Ireland
Abstract
Quantified, performance indicators for dynamic mode Differential GPS (DGPS) were collected at 31 sites established under 3 canopy classes (none, pre-first thinning and mature) of Sitka spruce stands in Ireland with varying altitude (100-500 m) and aspect. Canopy cover was quantified using total obstruction, size of largest opening and fragmentation of sky view. At sites with no canopy above 2 m, a mean precision of 1.5 m was recorded. Where canopy was present, precision ranged between 2.6 m and 2.8 m. The results indicated that in dynamic mode, differences in DGPS performance between canopy cover types were limited to a presence/absence effect. oss of 3-dimensional operation (i.e. only 3 satellites in view) occurred more frequently than loss of differential correction signal and thus had a greater impact on recorded precision over the duration of the experiment. It was concluded from the data collected that the most versatile approach when using dynamic DGPS is to collect more (potentially poorer quality) data, rather than to apply a filter at the signal acquisition stage. The observations made, and the conclusions drawn in this paper are relevant to the forest industry in the selection and operation of DGPS equipment for dynamic tasks where ~ 2 m precision is required.